Showing posts with label crankcase. Show all posts
Showing posts with label crankcase. Show all posts

Monday, May 20, 2013

MV ASIR crankcase explosion








M.V ASIR Incident

[05-12-2013]
UNITED ARAB SHIPPING COMPANY (SAG) regrets to report that on or about 0835 hrs. UTC on May 11, 2013, off Abu Elkizan Island (25-01 N and 036-05 E) an explosion occurred in the Engine Room of its vessel m.v. ASIR en route from Suez to Jeddah resulting in the loss of power of the vessel besides injuries to three of its officers. Two of the injured officers have already been removed from the vessel for medical treatment. The vessel is now on emergency power and has developed a slow drift. UASC has already entered into towage contracts for moving the vessel to Jeddah where she was originally bound.
The UASC vessel mv JEBEL ALI is near m.v. ASIR providing standby assistance until the towage operations commence. Efforts are continuing to restore power to the vessel. There is no damage to cargo nor any pollution on board the vessel or at sea but the towage operations may entail a couple of days after which the cargo on board would be discharged.
UASC regrets the inconvenience caused to its customers and Partners on account of the incident but is taking all steps to minimize the hardship to the extent possible.
A further press release will follow regarding the discharge and delivery of cargo on board the vessel once the time lines are more clearly known closer to the conclusion of towage operations.

M.V. ASIR - 2nd update

[05-19-2013]
Further to the communication dated May 12, 2013, UASC is pleased to inform having engaged the services of 2 Tugs from Smit Salvage to move the vessel to Jeddah. Informatively full power was restored to the generators prior to the commencement of towage around 0100 hrs on May 13, 2013. Prior to the arrival of tugs, UASC vessels mv AIN SNAN and mv JEBEL ALI had, in turns, extended emergency support to vessel.
The towage operations commenced on May 15, 2013 around 0845 hrs UTC and the vessel was cast off by the Smit tugs at OPL Jeddah on or about 1612 hrs local time on May 18, 2013 when four tugs belonging to the Saudi Port Authority took over and towed the vessel to Berth no: 51.at DPW Terminal in Jeddah. The vessel was all fast at the said berth on or about 2018 hrs local time.
m.v. “ASIR” is expected to complete the discharge of all 1841 containers on board around 2300 hrs local time on May 19, 2013. Subsequently she would be moved to the general cargo berth for inspection/emergency repairs.
The plan for transshipment of cargo discharged from mv ASIR at Jeddah and originally bound for Khorfakkan, Jebel Ali, Port Qassim and Nhava Sheva is as follows:
  • m.v. “AL MUTANABBI ” ETA Jeddah – 19.05.2013 am
    [Reefers for Jebel Ali and cargo for Nhava Sheva]
  • m.v. “HATTA” ETA Jeddah – 21.05.2013 am
    [All cargo for Arabian Gulf ports via Khorfakkan and Jebel Ali except Reefers for Jebel Ali]
  • m.v. “ABU DHABI” ETA Jeddah – 26.05.2013 am
    [All Port Qassim cargo]
Any change in plans to the above will be communicated to all concerned by UASC Agents.
UASC will extend all cooperation for inspection of cargo post discharge from mv ASIR.

http://www.uasc.net/news/130512/mv-asir-incident

Sunday, April 21, 2013

Crankcase Inspection of Compressor


Crankcase Inspection of Compressor
Risk Assessment:
Turn off the source and lock the button (additionally a warning TAG can be placed over the source that work is in progress.
Visit the machinery physically and ascertain any hazard during working.
Write on daily White board that work is in progress on Compressor No. 1 etc
Tools:
During visit to machinery remind in mind what proper tools which you will need during crankcase inspection.
We use the following tools during opening up of Crankcase.
·         17 milimeter Open and Close end spanner.
·         22 milimeter Open and Close end spanner.
·         A ball peen hammer
·         A flat screwdriver
·         Red RTV silicone
·         Adjustable spanner
·         Torque spanner with appropriate socket (we use 22mm)
·         Cloths for cleaning and empty bucket for pouring the dirty crankcase oil.
Commencement of Work:
Open up the Crankcase door by 17mm spanner. Remove the nut; door such that no harm to gasket. Check that there is no particle of metal in the sump. Check the Crank pin bearing nuts( by using 22mm spanner). If they are loosen tight it with the help of torque spanner at appropriate torque. Drain the Crankcase oil by removing the square nut. Clean the Crankcase and then pour some clean oil to drain it again. Tightened the square nut and replenish crankcase with new oil (Castrol SN 100). Our marking of compressor is 4cm (Min Level). Assemble the crankcase door and nut as in reverse process.  Start the Compressor  for trail run Check the ampere, Temperature, pressure of 1st , 2nd, water , oil gauge and any unusual sound if any. If the doubt persist stop the compressor immediately and check the compressor again.  


Written By
Zeeshan Ahmed
46th Batch PMA
92 334 4011232


See My Marine Engineering Works:-
my web: http://zeetec4.googlepages.com/
my blogs: http://shipengineer.blogspot.com/
my Picasaweb: http://tinyurl.com/marineapprentice




Wednesday, November 30, 2011

Know your ship. It's simple

Fouling and Fires in the Scavenge Air Spaces
The principle cause of fouling is blow-by of combustion products, unburnt fuel and cylinder lubricant between piston and cylinder into the scavenge air
spaces. The fouling will be greater if there is incomplete combustion of the fuel injected (exhaust smoke).
Causes of Poor Combustion:
The fuel injectors are not working correctly; incorrect fuel atomisation.
The fuel is at too low a temperature; resulting in high fuel viscosity and poor fuel atomisation.
Poorly adjusted injection pump timing; late injection results in after burning of fuel.
Operation with a temporary shortage of air during extreme variations in engine loading and with the charge air pressure dependent fuel limiter in the governor set too high.
Engine overloading; too much fuel for the available air.
Insufficient supply of air due to restricted engine room ventilation.
Fouling of the air intake filters and diffuser on the air side of the turbocharger.
Fouling of the air cooler, the air flaps in the charge air receiver and of the scavenge ports; these restrict air flow to the cylinders.
Fouling of the exhaust gas boiler; this increases the back pressure on the turbocharger turbines causing reduction in performance
and reduced air delivery.
Causes of Blow-by of Combustion Products:
Worn, sticking or broken piston rings.
Excessive liner wear or abnormal wear such as 'clover-leafing' which can also result in ring collapse and loss of piston ring to liner seal.
Individual cylinder lubricating quills are not working.


Damage to the running surface of the cylinder liners.
If one or more of these operating conditions prevails, residues, mainly consisting of incompletely burnt fuel and cylinder lubricating oil will
accumulate at the following points:
Between piston rings and piston ring grooves; this can result in the jamming of piston rings causing breakage or blow-past.
On the piston skirts. In the scavenge ports; this can affect the performance of the scavenging process resulting in incomplete
removal of combustion products from the cylinder and subsequent defective combustion.
On the bottom of the cylinder jacket (piston underside).
Causes of the Fires
The blow-by of hot combustion gases and sparks which have bypassed the piston rings between piston and cylinder liner running surface, enter the space
on the piston underside. Any residues present can ignite.
If there is after-burning of fuel in the cylinder due to late injection or poor fuel atomisation, the cylinder pressure, when the scavenge ports are uncovered, may be higher than the scavenge air pressure and hot combustion gases may enter the scavenge space.
A defective piston rod gland may allow oil from the crankcase to enter the scavenge space. The piston rod gland drains should be checked frequently for
signs of crankcase system oil as this indicates defective gland sealing rings.

Indications of a Fire
Sounding of the respective temperature alarms if the engine has the necessary monitoring instrumentation installed.
A considerable rise in the exhaust gas temperatures of the cylinder concerned and a general rise in charge air temperature.
The turbocharger may start surging.


Scavenge Space Fire Fighting Measures
The safety of shipboard personnel should be paramount whenever dealing with fires anywhere aboard ship.
Inform the bridge of the situation
Reduce engine power
Cut out the fuel injection pump of the cylinder concerned
Increase lubrication to the respective cylinder
(Note! If a serious fire occurs, shut down the engine after obtaining permission from the bridge and operate the fixed fire extinguishing system.)
A fire should have died down after 5 to 15 minutes. This can be verified by checking the exhaust gas temperatures and the temperatures of the doors to the piston bottoms.
Caution should be exercised whilst the fire is burning to ensure that it does not cause a fire in the engine room. Extreme care must be taken to ensure that
leakage of oil onto the hot scavenge space sides does not happen.
After it has been confirmed that the fire has been extinguished the engine must be stopped as soon as possible and the cause of the fire established. The
scavenge space must be allowed to cool completely before access doors are opened to allow inspection.
Checks should be made on the cylinder running surfaces, piston rings, fuel injectors, valve groups in the scavenge space, piston rod gland and liner seals.
Tie rod tension should be checked if the fire has been severe.
After a careful check, or if necessary repair, the engine can be put back on load with cut-in fuel injection pump and automatic cylinder lubrication.
Should a stoppage of the engine not be feasible and the fire has died down, the fuel injection pump can again be cut in, the load increased slowly and the
cylinder lubrication brought back again to the normal output. Avoid prolonged running with the considerably increased cylinder lubrication.
Preventive Measures
As can be seen from the causes, good engine maintenance goes a long way to safeguarding against fires in the scavenge air spaces. The following measures have a particularly favourable influence:
Use of correctly spraying fuel injectors and keeping the air and gas passages clean.
Optimum adjustment of the fuel cams and of the fuel injection pump timing.
When running continuously at reduced load, check the cylinder lubricating oil feed rate and readjust if necessary. Ensure that fuel atomisation and combustion is correct for the reduced load condition.
The permanent drain of residue from the piston underside must always be checked. To prevent accumulation of dirt, the drain cock on the collector main must be opened for a short time each day.
Prevention of Crankcase Explosions
The oil mist in the crankcase is inflammable over a very narrow range of mixture. Weaker or richer mixtures do not ignite. There must always be an
extraneous cause to set off ignition, such as hot engine components. Only under these circumstances and the presence of a critical mixture ratio of oil
mist and air can an explosion occur. A 'hot spot' is the common feature of all crankcase explosions and this can be due to metal-to-metal contact at a wiped bearing, rubbing guide, defective piston rod gland, damaged thrust, un-lubricated gear wheel, etc. or even due to a prolonged scavenge fire. The 'hot spot' provides the heat source to evaporate oil, which condenses to form mist-like droplets which will ignite readily, and ignite the mist. If the mist concentration in the crankcase reaches a critical level an explosion can occur.
Engines are equipped with an oil mist detector, which constantly monitors intensity of oil mist in the crankcase and triggers an alarm if the mist exceeds
the density limit.
Measures to be Taken When Oil Mist Has Occurred
a)  Do not stand near crankcase doors or relief valves or in corridors near doors to the engine room casing.
b)  Reduce speed to slowdown level immediately, if not already carried out automatically. Explain the situation and ask the bridge
for permission to stop.
c)  When the engine STOP order is received, stop the engine. Close the fuel oil supply. Maintain engine cooling and lubrication as the supply of lubricant will assist the cooling of the hot spot.
d)  Switch-off the auxiliary blowers.
e)  Open the skylight(s) and/or stores hatch.
f)   Leave the engine room as a fire can still occur even with the engine stopped because the mist will circulate in the crankcase and can come into contact with the hot spot.
g)  Lock the casing doors and keep away from them,


h) Prepare the fire-fighting equipment.
i) Do not open the crankcase until at least 20 minutes after stopping the engine. Ideally leave the engine for as long as possible before opening the crankcase doors as this will ensure that the hot spot has cooled below the ignition temperature and so any mist which persists will not ignite from this source. It is important that no naked lights exist in the vicinity of the crankcase when the doors are opened in order to prevent ignition of any residual mist from that source.
j) Stop the lubricating oil pump. Take off-open all the doors on one side of the crankcase. Cut off the starting air, and engage the turning gear.
Main Engine Graviner Oil Mist Detector

k) Locate the hot spot. Feel over, by hand, all the sliding surfaces (bearings, thrust bearing, piston rods, stuffing boxes, crossheads, lubricant supply toggle lever pipes, gears, vibration dampers, moment compensators, etc.)- Look for squeezed-out bearing metal and discolouration caused by heat (blistered paint, burnt oil, oxidised steel). Keep possible bearing metal found at the bottom of the oil tray for later analysing. Prevent further hot spots by
preferably making a permanent repair. Ensure that the respective sliding surfaces are in good condition. Take special care to check that the circulating oil supply is in order. The engine should not be restarted until the cause of the hot spot has been located and rectified.
1) Start the circulating oil pump and turn the engine by means of the turning gear. Check the oil flow from all bearings, spray pipes and spray nozzles in the crankcase, camshaft drive gear wheel case and thrust bearing. Check for possible leakages from pistons or piston rods.
m) Start the engine. After running for about 30 minutes stop and feel over surfaces for signs of abnormal temperature rise. Especially feel over the sliding surfaces which caused the overheating. There is a possibility that the oil mist is due to atomisation of the circulating oil, caused by a jet of air/gas, e.g. by combination of the following: Stuffing box leakages (not air tight). Blow-by through a cracked piston crown or piston rod (with direct connection to crankcase via the cooling oil outlet pipe). An oil mist could also develop as a result of heat from a scavenge fire being transmitted down the piston rod or via the stuffing box. Hot air jets or flames could also have passed through the stuffing box
into the crankcase.
WARNING
Special Engine Room Dangers
Keep clear of spaces below loaded cranes.
The opening of cocks may cause discharge of hot liquids or gases.
The dismantling of parts may cause the release of springs.
The removal of fuel valves or other valves in the cylinder cover may cause oil to run onto the piston crown. If the piston is hot an explosion may blow out the valve.
When testing fuel valves do not touch the spray holes as the jets may pierce the skin.
Beware of high-pressure oil leaks when using hydraulic equipment, wear protective clothing.
Arrange indicator cocks with pressure relief holes directed away from personnel, wear goggles when using indicator equipment.
Do not weld in the engine room if the crankcase is opened before fully cooled.
Turning gear must be engaged before working on or inside the engine as the wake from other ships in port or waves at sea may cause the propeller to turn. Also, isolate the starting air supply.
Use warning notices at the turning gear starter and other control stations to warn personnel that people are working on the engine.
Use gloves when removing O-rings and other rubber/plastic based sealing materials, which have been subjected to abnormally high
working temperatures as they may have a caustic effect.
Do not allow oil patches to remain on floors as personnel can easily slip resulting in injury.
Oil spills, and particularly oily rags, anywhere present a fire hazard.
Do not remove fire extinguishers from designated positions and ensure that any fire extinguishers which have been used are replenished immediately.
Only use lifting equipment which has current certification.

Wednesday, June 22, 2011

Crankcase oil mist detector

In the name of Allah who is the most beneficient and merciful               

This device is fitted to monitor the presence of an oil mist in the crankcase. In this monitoring process samples of the air and vapours mixture taken continually from the crankcase of a diesel engine. This device will detect the level of oil mist concentration which must remain below level. At which explosion may occur. In case of coming to this level a warning is given to allow avoiding action to slow the engineer and prevent serious damages and explosion.

The presence of an oil mist in the crankcase is the result of oil vaporization caused by a “Hot spot” this hotspot is produced by other heating of any engine bearing or overheating of any other moving parts of the engine time chain or gear drives. Explosive condition can result if build up of oil mist is allowed. Hence continuous monitoring of vapours intensity is required. A diagrammatic view of an oil mist detector is shown in the sketch.

Measure any increase in oil mist density. The detector consists basically of two parallel tubes of equalize, each having an electric current directly proportional to the intensity of light falling on the surface. Lenses are fitted to seal the tube ends of each tube but allow light to pass. One tube is sealed to contain clean air and is termed the reference tube. The other tube is called Measuring tube, has connections through which samples of the crankcase vapours are drawn by extractor fan. If the concentration of explosive mixture is reached in the oil mist sample, light will be obscured(not clear) before reaching the cell of measuring tube, electrical balance between two cells will be disturbed and an alarm will be operated indicating excess concentrations in oil mist. Sampling points should be fitted to each cylinders crankcase and their connections are brought to a rotating selector valve which is driven from the fan motor. This repeatedly connects each sampling point  to the measuring tube in sequence.

In the event of oil mist being detected the rotator stops to indicate which sampling will commence again its sequence.
The detector should be checked daily and the sensitivity tested. Lenses and mirrors should be cleaned periodically. Two identical beams of light from a common lamp are reflected by mirrors to pass along the tube on to the cells which are then in electrical balance and if light will be obscured before reaching the cells, electrical balance will be distured and an alarm will be operated.


WRITTEN BY: S/C ZEESHAN AHMED
LECTURED BY: CH. ENGR. YASEEN SAHAB
DATE: 23/OCT/2009
TIME: 11:17 AM